CISTOURETROGRAFIA MICCIONAL PDF

Publisher: En , la Academia Americana de Pediatría recomendó realizar una ecografía renal y una cistouretrografía miccional a todos los. O paciente foi então submetido a uma cistouretrografia miccional, que revelou bexiga com capacidade normal, de contornos trabeculados e formações. Cistouretrografía miccional seriada. (CUMS): Esta técnica informa sobre la presencia de reflujo vésico-ureteral, sobre las características de la uretra proximal y.

Author: Nami Kazralkis
Country: Cambodia
Language: English (Spanish)
Genre: Environment
Published (Last): 4 June 2004
Pages: 97
PDF File Size: 11.17 Mb
ePub File Size: 1.73 Mb
ISBN: 583-3-12177-192-8
Downloads: 5956
Price: Free* [*Free Regsitration Required]
Uploader: Kesar

cistouretrografía miccional con TV | Spanish to English | Medical: Health Care

Saudi J Kidney Dis Transpl. Close and don’t show again Close. On the other hand, Ruiz et al. Icstouretrografia this catheter, iodinated contrast medium diluted in saline solution is administered, and anteroposterior radiographs are made during the vesical filling, at the low, medium and full micciinal stages. One of these units produced a DAP five times higher than the other and 4, cGy.

For being anatomically related with the genital area where the ovaries that cannot be protected and testicles that can be partially protected from the inherent high examination dose by means of gonad protectorsthis imaging method causes a great exposure of these structures that jiccional so sensitive to radiation. However, even being such use justifiable by the benefits to patients, standards and radioprotection techniques cannot be forgotten.

Patents, Trademarks, Copyright Law: Patient dose reduction during voiding cystourethrography.

There was a problem providing the content you requested

Login to enter a peer comment or grade. The observation of total ESD ranging from 17 to The body mass index BMI was calculated and ranged from Total DAP ranged from to 1, cGy. In the present study, one of the factors that contributed for the magnitude of entrance skin doses was the lack of cistouretrpgrafia of the radiographic imaging techniques employed.

After the voiding is completed, anteroposterior abdominal radiography is performed to evaluate the degree of vesical emptying and the presence or not of vesicoureteral reflux. Return to KudoZ list. El problema es el cistouretroggafia TV” Dose-area product values in frequently performed complex paediatric radiology examinations. Evaluation of work practices and radiation dose during adult micturating cistouretroografia examinations performed using a digital imaging system.

Pediatric radiation exposure and effective dose reduction during voiding cystourethrography.

cistouretrografía miccional con TV

The dose delivered to the patient in voiding cystourethrography is high, with fluoroscopy being its primary contributor. Only one child might be considered obese, which does not influence the average technical factors. However, all of them used fluoroscopy for an extended time, increasing the radiation dose delivered to the patient. You have native languages that can be verified You can request verification for native languages by completing a simple application that takes only a couple of minutes.

  LA AVENTURA ANTARCTICA DEL ENDURANCE PDF

You can request verification for native languages by completing a simple application that takes only a couple of minutes. The comparison of doses in relation to sex demonstrated that, in spite the higher mean body mass index for girls, the dose on the boys was higher Table 4probably because of the inherent difficulties presented by the male anatomy, and the higher number of abnormal studies in boys, which caused greater time in fluoroscopy, and increase in dose.

However, considering the present guidelines, one out of four patients would have been exposed miccioonal a delayed or potentially missed diagnosis if recurrence would have been expected to complete the assessment. Login or register free and only takes a few minutes to participate in this question. Considering that the fluoroscopy time ranged from 82 to 1, seconds mean, secondsthe authors can suggest a radical reduction of this time.

Most recent studies 19,20 cistouretrorgafia the utilization of technically more updated equipment, with the so called pulsed fluoroscopy, which considerably reduces the total dose, by directly influencing the fluoroscopy dose reduction. Radiation dose reduction in paediatric fluoroscopy using added filtration.

To micciomal dose-area product, skin entrance dose and doses from fluoroscopy and radiography in voiding cystourethrography studies of pediatric patients. This fact can be explained by the abnormal studies, which require additional incidences to adequately document alterations in the urinary tract such as, for example, the presence of bladder diverticula, male urethral abnormalities and other more complex abnormalities.

The authors’ findings allow them to suggest that both DAP and ESD are good parameters to evaluate appropriate dose levels for voiding cystourethrography. One should remember that some radiologists perform the examination without using fluoroscopy, because they have learned to do so, in a time when image intensifiers were not available. This hospital is a reference in neonatology, pediatric surgery and medical genetics; consequently, the number of patients with congenital abnormalities is very high, with frequent cases of urinary abnormalities.

The prevalence of a cistouretroyrafia pathology among patients studied as per the guidelines 9 out of 24 niccional, 3 with atypical UTI or as per the guidelines 11 out of 21 cases was similar The limitation of the fluoroscopy area only to the area of interest, even in equipment with automatic collimation as a function of the programmed film division, could be an additional dose reducing factor in these higher patients.

  DAN ABNETT XENOS PDF

This chamber, positioned immediately below the collimator, registers the radiation emitted by the bulb during the examination time, monitoring the DAP and ESD in the patient being submitted to radiography and fluoroscopy.

Paediatric x-ray examinations in Rio de Janeiro. Some procedures heterogeneity was observed and guidelines for good radiographic techniques were not followed. English PRO pts in category: Vote Promote or demote ideas. Term search All of ProZ. Reviewing applications can be micciional and only takes a few minutes.

In a review of similar studies in developed in other countries, one can better evaluate such difference. Inthe American Academy miccionap Pediatrics AAP recommended perform a renal ultrasonography and avoiding cystourethrography to all infants between 2 and 24 months of age after their first urinary tract infection UTI.

One can determine the radiation dose incident on the exposed areas by using the Cistouretrografis, a device that is coupled to the x-ray tube that allows the monitoring of accumulative radiation emitted by the x-ray tube during the examination, and which will not interfere on the procedure performance.

Assessment of dosimetric quantities for patients undergoing X-ray examinations in a large public hospital in Brazil – a preliminary study. Automatic update in The patients were divided into four age groups: In this latter hospital, the fluoroscopy time ranged from 0. The adoption of radiography with high kilovoltage technique and restricted utilization of fluoroscopy can result in a significant reduction of doses during this procedure, considering that the major contribution to the final dose comes from fluoroscopy.

In an important Brazilian Institution of pediatric radiology, the doses are above those found in similar studies. Evaluation of radiation dose in voiding cystourethrography in children.

Measurements were performed with an equipment including an ionization chamber cistouretografia coupled to the x-ray tube window and an electrometer Diamentor connected to a computer for data collection.